it's all in the detail.

excellent flow rates

In a flow rate analysis of various infusion sets, the GRIPPER® Micro needle demonstrated approximately 40% greater flow than other competitors needles tested*

Allows for use of a smaller needle gauge size during insertion and blood draws to help minimize patient discomfort

  • The blunt cannula allows for 360° flushing and flow in the port, helping to reduce the risk of build-up within the portal chamber
  • The unique design of the blunt cannula ensures it remains elevated above the port reservoir floor so flow will not be obstructed

9 reasons the GRIPPER® Micro needle helps promote all around safety

  1. Luer is fully threaded

    • Helps to minimize the risk of accidental disconnection
  2. TOTM-plasticized PVC tubing

    • Kink-resistant
    • Compatible with medications such as lipids and Taxol®
  3. Color-coded C-clamps

    • Easy identification of needle gauges:

      • Beige = 19G
      • Yellow = 20G
      • Black = 22G
      • Needle length is printed on the clamp insert
    • One clamp (non Y-site version)
    • Two clamps (Y-site version)
  4. Y-site, Luer-activated Needle-free Injection Site (NAC)

    • NAC (Needle-free Access Connector) is non-removable and can be used with any standard Luer device such as a syringe or IV tubing
  5. Inserter

    • Contoured ergonomic grip promotes controlled needle placement
    • Circle at the top of the inserter assists with visual placement of the needle into the port
    • Needle used for insertion is a non-coring trocar needle and is removed immediately after insertion into a port. The patient will not feel the needle being removed as it does not pass back through the skin
    • The back edges of the inserter are rounded to improve patient comfort during activation of the safety needle
  6. Infusion site

    • Non-siliconized blunt cannula for secure retention
    • The blunt cannula is considered by OSHA to be a "needleless system". OSHA's definition is: A device that does not use needles for the collection of bodily fluids or withdrawal of body fluids after initial venous or arterial access is established. [http://www.osha.gov (29 CFR 1910.1030)]
    • Cushion is designed to promote patient comfort for long term infusions. Closed-cell foam helps prevent absorption of moisture and bacteria into the foam which may help prevent skin breakdown
    • Small size and low profile of the infusion site allows clinician better assessment of the access site
  7. Flow Rate

    • According to the Measurement of Flow Rate for the GRIPPER® Micro needle white paper, the GRIPPER® Micro needle demonstrated approximately 40% greater flow than the other competitor infusion needles tested²
    • The blunt cannula allows for 360 degree flushing and flow in the port which helps reduce the chance for any build-up within the port
    • The unique design of the blunt cannula in the GRIPPER® Micro needle helps it remain elevated above the reservoir floor, so flow will not be obstructed
  8. Non-Coring

    • The GRIPPER® Micro needle is non-coring due to the solid trocar which is inside the blunt cannula during insertion
  9. Needle sharpness